Shot lists · Shot list
Multifamily (income property) shot list: what investors need to see
Updated 10 Nov 2026 · by Venu Gopal Reddy Muvva, founder · rules checked 10 Nov 2026 on the official pages below
A multifamily or income property needs about 25–30 photos: the building exterior and lot, one representative set for each unit type, shared areas, laundry, parking, and the systems an investor will pay to maintain — meters, boiler or water heaters, electrical panels and the roof. Lead with the building exterior, because investors first judge condition, size and location, then look for evidence of maintenance costs.
The shot list
Multifamily shot list in shooting order (full-frame equivalent).
| Shot | Angle | Lens / height | Why |
|---|---|---|---|
| 1. Building front | Two-thirds from the street | 20–24 mm, 1.5–1.8 m | Lead: size and condition |
| 2. Building side and rear | From the lot corners | 20–24 mm, 1.5 m | Siding, windows, fire escapes |
| 3. Street view | Both directions | 24 mm, 1.5 m | Location |
| 4. Aerial | Drone 30–60 m | Drone | Lot, parking, roof overview |
| 5. Entry and common hall | From the front door | 20 mm, 1.2 m | Upkeep of shared spaces |
| 6. Common stairs | From the bottom | 16–20 mm, 1 m | Condition and safety |
| 7. Unit type A living | Corner | 16–20 mm, 1.1 m | Representative unit |
| 8. Unit type A kitchen | Wide | 16–20 mm, counter height | Finish level drives rent |
| 9. Unit type A bedroom | Corner | 16–20 mm, 1 m | Size |
| 10. Unit type A bath | From door | 16 mm, 1 m | Condition |
| 11–14. Unit type B (same four) | As above | As above | Each layout or finish level once |
| 15. Renovated vs original unit | Kitchen of each | Same framing | Shows value-add potential |
| 16. Shared laundry room | Wide | 16–20 mm, 1.2 m | Laundry income or amenity |
| 17. Parking lot or garages | Wide | 20 mm, 1.5 m | Spaces per unit |
| 18. Electric meters | Straight on, all meters in frame | 24–35 mm, 1.5 m | Separately metered units |
| 19. Gas meters | Straight on | 24–35 mm, 1.2 m | Who pays utilities |
| 20. Boiler or water heaters | From the doorway | 16–20 mm, 1.2 m | Age and type of system |
| 21. Electrical panels | Closed panel, label visible | 35 mm, 1.5 m | Service size |
| 22. Roof | From roof access or drone | 16–20 mm or drone | Roof age and condition |
| 23. Basement or storage | Wide | 16–20 mm, 1.1 m | Storage income or space |
| 24. Yard or outdoor area | Wide | 20 mm, 1.5 m | Tenant amenity |
| 25. Mailboxes | Straight on | 24–35 mm, 1.5 m | Unit count at a glance |
| 26. Building at twilight (optional) | Same as 1 | 20–24 mm, 1.5 m | Alternate lead for larger buildings |
| 27. Site plan or floor plans | Drawn per unit type | — | Layout per type |
Order of shooting
- Arrange access with tenants in writing; most jurisdictions require notice before entering an occupied unit.
- Exteriors and aerial first, then common areas, then the vacant or prepared units, then mechanicals in the basement, then roof.
- Shoot one unit of each type rather than every unit; caption the type and how many of that type exist.
- Keep tenants' personal items, mail and documents out of frame.
What multifamily investors look for
Investors read the photos for costs and upside. They check the roof, boiler, water heaters, electrical service and windows (big future costs), whether units are separately metered (who pays utilities), laundry and parking (extra income), and the gap between original and renovated units (value-add). A clean exterior lead and an honest mechanicals set build more trust with investors than styled interiors.
Put unit mix, current rents and occupancy in the description, not on photos; most MLSs ban text on images.
Common mistakes
- Photographing occupied units without notice or with tenants' belongings and documents visible.
- Skipping meters and mechanicals, which investors then assume are old.
- Showing only the one renovated unit, implying all are renovated.
- Text overlays with rents or cap rates on photos, which most MLSs forbid.
Worked example: a fourplex with two unit types
Order: front (lead), side and rear, street, aerial, entry hall, stairs, unit type A (2-bed, 3 units) living, kitchen, bedroom, bath, unit type B (1-bed, 1 unit) living, kitchen, bedroom, bath, renovated vs original kitchen, coin laundry, six-space lot, four electric meters ('separately metered'), gas meters, boiler room, panels, roof, basement storage, yard, mailboxes, floor plans for both types.
Editing and delivery
ListingPhotoStudio merges brackets, straightens building verticals and replaces a grey sky with blue on exteriors, scoring each photo 0–100. It does not change buildings or remove fixtures, which is what investors and MLS rules expect.
Make it a checklist
Turn this list into a printable checklist for your property's rooms and extras with the free shot list generator. It runs in your browser; nothing is sent to our server.
Questions
Do I need to photograph every unit in a multifamily building?
No. Photograph one representative unit of each type and say how many of each exist.
Why photograph meters and the boiler?
Investors use them to judge who pays utilities and what big repairs are coming.
Can I put rents or cap rate on the photos?
Most MLSs ban text on listing photos. Put the numbers in the description or a separate document.
How many photos does a small apartment building need?
About 25–30: exteriors, common areas, one set per unit type, laundry, parking, mechanicals and roof.
Sources
- NWMLS: Real Estate Photography 101 — checked 10 Nov 2026
- Stellar MLS: Rules & Tips for MLS Listing Photos — checked 10 Nov 2026
We are not affiliated with any portal or MLS named here. Rules change: confirm on the linked official page before you rely on a number. General information, not legal advice.
ListingPhotoStudio edits listing photos (HDR, window pull, sky, straight verticals) and gives you MLS-sized, unbranded downloads with a quality score on every photo. Free for 14 days.
Related: Independent house shot list: floors, terrace, puja room and water · Aerial and drone listing photos · Basement listing photos: light, height and honesty · Front exterior photo for a listing · Logos, watermarks and text on listing photos · All shot lists